{"id":2315,"date":"2026-05-23T16:20:49","date_gmt":"2026-05-23T13:20:49","guid":{"rendered":"https:\/\/enmos.com\/?page_id=2315"},"modified":"2026-09-17T03:50:12","modified_gmt":"2026-09-17T00:50:12","slug":"apre-kimyasal-otomasyonu-2","status":"publish","type":"page","link":"https:\/\/enmos.com\/en\/urunler\/kimyasal-otomasyon\/apre-kimyasal-otomasyonu-2\/","title":{"rendered":"Finishing Chemical Automation"},"content":{"rendered":"<div class=\"enmos-product-page\" style=\"--lead-en:82ch;--gorsel-dolgu:34px\">\n          <div class=\"enmos-container\">\n\n            <section class=\"product-head\">\n                              <div class=\"eyebrow\">Finishing Chemical Automation<\/div>\n                            <h1 class=\"product-title\">Profix CS<\/h1>\n                              <div class=\"product-subtitle\">Stenter Chemicals Dosing System<\/div>\n                                            <p class=\"product-lead\">Profix CS is a finishing chemical automation system designed for the liquid chemical needs of stenter machines. It weighs even high-viscosity stenter chemicals accurately and stably, with automatic ordering, padder dosing control and detailed reporting.<\/p>\n                          <\/section>\n\n            <div class=\"product-layout\">\n              <aside class=\"product-sidebar\">\n                                  <h3 class=\"sidebar-title\">Content<\/h3>\n                  <nav class=\"sidebar-nav\">\n                                          <a href=\"#gorsel\">Product Image<\/a>\n                                          <a href=\"#bolum-genel-bakis\">Overview<\/a>\n                                          <a href=\"#bolum-one-cikanlar\">Highlights<\/a>\n                                          <a href=\"#bolum-genel-ozellikler\">General Specifications<\/a>\n                                          <a href=\"#bolum-opsiyonel-ozellikler\">Optional Features<\/a>\n                                          <a href=\"#bolum-teknik-ozellikler\">Technical Specifications<\/a>\n                                      <\/nav>\n                                                  <div class=\"sidebar-mini\">\n                    <strong>RAM<\/strong>\n                    <span>Developed for the liquid chemical requirements of stenter machines.<\/span>\n                  <\/div>\n                                  <div class=\"sidebar-mini\">\n                    <strong>0.5%<\/strong>\n                    <span>Provides stable weighing and dosing support through measurement accuracy.<\/span>\n                  <\/div>\n                                  <div class=\"sidebar-mini\">\n                    <strong>48<\/strong>\n                    <span>Offers a broad system structure with maximum chemical connections.<\/span>\n                  <\/div>\n                              <\/aside>\n\n              <main class=\"product-content\">\n\n                \n                                  <section class=\"product-image-card\" id=\"gorsel\">\n                    <div class=\"image-frame\">\n                      <img decoding=\"async\" src=\"https:\/\/enmos.com\/wp-content\/uploads\/2026\/05\/Profix-CS.png\"\n                           alt=\"Profix CS\" loading=\"lazy\">\n                    <\/div>\n                  <\/section>\n                \n                                  <section class=\"content-section\" id=\"bolum-genel-bakis\">\n                                          <h2 class=\"section-title\">Overview<\/h2>\n                                        <p class=\"section-text\">Profix CS is a dedicated system designed for dosing the liquid chemicals used on stenter machines. Thanks to its mass flowmeter, even high-viscosity stenter chemicals are weighed accurately and stably.<\/p><p class=\"section-text\">It separates high-volume chemicals to the stenter machines independently of the dyeing machines, minimising time loss. Thanks to its different washing procedures, it offers cold water, hot water and other options for chemicals with high viscosity and stickiness.<\/p><p class=\"section-text\">Delivery speed can be set parametrically according to emission breakdown values, one of the critical properties of stenter chemicals. With S-588 external control, automatic ordering and padder dosing control, it reduces much of the workload in the finishing section.<\/p>                  <\/section>\n                                  <section class=\"content-section\" id=\"bolum-one-cikanlar\">\n                                          <h2 class=\"section-title\">Highlights<\/h2>\n                                                        <div class=\"highlight-grid\">\n                                      <article class=\"highlight-card\">\n                      <div class=\"highlight-title-badge\">Stenter Chemical Dosing<\/div>\n                      <p>Its structure, designed for the liquid chemical needs of stenter machines, brings high-volume chemical use under better control.<\/p>                    <\/article>\n                                      <article class=\"highlight-card\">\n                      <div class=\"highlight-title-badge\">Stable Weighing<\/div>\n                      <p>Its mass flowmeter structure ensures even high-viscosity stenter chemicals are weighed accurately and stably.<\/p>                    <\/article>\n                                      <article class=\"highlight-card\">\n                      <div class=\"highlight-title-badge\">Parametric Delivery<\/div>\n                      <p>Chemical delivery speed can be set parametrically according to emission breakdown values and optimised for process needs.<\/p>                    <\/article>\n                                  <\/div>\n                              <\/section>\n                                  <section class=\"content-section\" id=\"bolum-genel-ozellikler\">\n                                          <h2 class=\"section-title\">General Specifications<\/h2>\n                                                        <ul class=\"usage-list\">\n                                      <li>Ease of installation, relocation and upgrading<\/li>\n                                      <li>Touchscreen<\/li>\n                                      <li>Multiple water line inlets for line cleaning<\/li>\n                                      <li>Detailed reporting and analysis software<\/li>\n                                      <li>Purpose-designed valves for line cleaning<\/li>\n                                      <li>Stenter chemical dosing<\/li>\n                                      <li>Minimal service and maintenance thanks to its design<\/li>\n                                      <li>Valve leak test system<\/li>\n                                      <li>Remote access and control<\/li>\n                                      <li>Online tank level monitoring<\/li>\n                                      <li>Integrated operation with ERP software<\/li>\n                                  <\/ul>\n                              <\/section>\n                                  <section class=\"content-section\" id=\"bolum-opsiyonel-ozellikler\">\n                                          <h2 class=\"section-title\">Optional Features<\/h2>\n                                                        <ul class=\"usage-list\">\n                                      <li>Management of up to 10 dosing tanks<\/li>\n                                      <li>Multi-stage washing procedure<\/li>\n                                      <li>Simplex 588 HMI support<\/li>\n                                      <li>Hot, cold and acid washing<\/li>\n                                      <li>Automatic recipe ordering<\/li>\n                                      <li>Tank farm<\/li>\n                                  <\/ul>\n                              <\/section>\n                                  <section class=\"content-section\" id=\"bolum-teknik-ozellikler\">\n                                          <h2 class=\"section-title\">Technical Specifications<\/h2>\n                                                        <table class=\"spec-table\">\n                                      <tr>\n                      <th>Product Name<\/th>\n                      <td>Profix CS<\/td>\n                    <\/tr>\n                                      <tr>\n                      <th>Category<\/th>\n                      <td>Finishing chemical automation \/ stenter chemicals dosing system<\/td>\n                    <\/tr>\n                                      <tr>\n                      <th>Max. Chemical Connections<\/th>\n                      <td>48<\/td>\n                    <\/tr>\n                                      <tr>\n                      <th>Weighing Quantities<\/th>\n                      <td>100 g - 100 kg, limited by software<\/td>\n                    <\/tr>\n                                      <tr>\n                      <th>Manifold Type<\/th>\n                      <td>Up to 4 manifolds, each holding 12 chemicals<\/td>\n                    <\/tr>\n                                      <tr>\n                      <th>Pump<\/th>\n                      <td>Centrifugal or lobe type, PID drive controlled<\/td>\n                    <\/tr>\n                                      <tr>\n                      <th>Max. Manifold<\/th>\n                      <td>1<\/td>\n                    <\/tr>\n                                      <tr>\n                      <th>Washing<\/th>\n                      <td>Parametric washing system<\/td>\n                    <\/tr>\n                                      <tr>\n                      <th>Distribution Type<\/th>\n                      <td>Single line, optional multi-line<\/td>\n                    <\/tr>\n                                      <tr>\n                      <th>Water Inlet Diameter<\/th>\n                      <td>1 hot and cold<\/td>\n                    <\/tr>\n                                      <tr>\n                      <th>Measurement Accuracy<\/th>\n                      <td>0.5%<\/td>\n                    <\/tr>\n                                      <tr>\n                      <th>Chemical Inlet Diameter<\/th>\n                      <td>1<\/td>\n                    <\/tr>\n                                      <tr>\n                      <th>Flowmeter Type<\/th>\n                      <td>Magnetic, optional MASS<\/td>\n                    <\/tr>\n                                      <tr>\n                      <th>Machine Outlet Diameter<\/th>\n                      <td>25.4 mm SS piston valve<\/td>\n                    <\/tr>\n                                      <tr>\n                      <th>Valve Positioner<\/th>\n                      <td>Standard<\/td>\n                    <\/tr>\n                                  <\/table>\n                                  <\/section>\n                \n                \n                \n                \n                                                  <section class=\"footer-panel\" id=\"sonuc\">\n                                          <h2>Accurate dosing, stable weighing and low loss in the finishing section<\/h2>\n                                                              <p>Profix CS is a comprehensive finishing chemical automation solution developed for accurately weighing, dosing, washing, monitoring and reporting stenter chemicals. It handles high-viscosity chemicals with a parametric washing system, automatic recipe ordering and padder dosing control.<\/p>\n                                                              <div class=\"footer-tags\">\n                                                  <span>Profix CS<\/span>\n                                                  <span>Finishing Chemical Automation<\/span>\n                                                  <span>Stenter Chemicals<\/span>\n                                                  <span>Mass Flowmeter<\/span>\n                                                  <span>0.5% Accuracy<\/span>\n                                                  <span>ERP Integration<\/span>\n                                                  <span>Padder Dosing Control<\/span>\n                                              <\/div>\n                                      <\/section>\n                \n              <\/main>\n            <\/div>\n\n                                      <div class=\"enmos-back-wrap\">\n                                <a href=\"\/en\/urunler\/kimyasal-otomasyon\/\" class=\"enmos-back-btn\">\n                  <div class=\"enmos-back-icon\"><div class=\"enmos-back-arrow\"><\/div><\/div>\n                  <div class=\"enmos-back-text\">\n                    <small>Back<\/small>\n                    <span>Kimyasal Otomasyon Sayfas\u0131na Geri D\u00f6n<\/span>\n                  <\/div>\n                <\/a>\n              <\/div>\n            \n          <\/div>\n        <\/div>","protected":false},"excerpt":{"rendered":"","protected":false},"author":1,"featured_media":0,"parent":1427,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"elementor_header_footer","meta":{"enmos_kart_baslik_en":"","enmos_kart_ozet":"","enmos_kart_ozet_en":"","enmos_kart_sira":"","footnotes":""},"class_list":["post-2315","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/enmos.com\/en\/wp-json\/wp\/v2\/pages\/2315","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/enmos.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/enmos.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/enmos.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/enmos.com\/en\/wp-json\/wp\/v2\/comments?post=2315"}],"version-history":[{"count":5,"href":"https:\/\/enmos.com\/en\/wp-json\/wp\/v2\/pages\/2315\/revisions"}],"predecessor-version":[{"id":2599,"href":"https:\/\/enmos.com\/en\/wp-json\/wp\/v2\/pages\/2315\/revisions\/2599"}],"up":[{"embeddable":true,"href":"https:\/\/enmos.com\/en\/wp-json\/wp\/v2\/pages\/1427"}],"wp:attachment":[{"href":"https:\/\/enmos.com\/en\/wp-json\/wp\/v2\/media?parent=2315"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}